Parameter channel (PKW)
4.2.5.5
PNU 1784: acceleration jolt limiting
For S400/S600 only. This parameter defines the form of the acceleration ramp.
If a value ¹ 0 is entered here, then a sin²-ramp (S-curve) is used to reach the target velocity.
To employ sine²-ramps, the configuration variable SPSET has to be set to 2 (via the ASCII-channel
or the ASCII-terminal in the setup software) and to be saved.
4.2.5.6
PNU 1786: deceleration time
This parameter defines the total time or rate (depending on the type of units selected for decelera-
tion) to reduce the velocity to 0 at the target position.
4.2.5.7
PNU 1787: deceleration jolt limiting
For S400/S600 only. This parameter defines the form of the braking/deceleration ramp.
If a value ¹ 0 is entered here, then a sin²-ramp (S-curve) is used for braking/deceleration.
4.2.5.8
PNU 1788: next motion task
S400/S600:
The motion task number of the motion task to be started can be from 1 to 180 (motion tasks in
EEPROM) or 192 to 255 (motion tasks in RAM).
S300/S700:
The motion task number of the motion task to be started can be from 1 bis 200 (motion tasks in
EEPROM) or 201 .. 300 (motion tasks in RAM).
4.2.5.9
PNU 1789: start delay
This parameter is used to set a delay time before the start of a motion task.
4.2.5.10
PNU 1310: copy motion task
This parameter can be used to copy motion tasks. The source motion task must be entered in the
high-value portion of PWE (PZD 5 & 6) and the target motion task must be entered in the low-value
portion of PWE (PZD 7 & 8).
4.2.5.11
PNU 1311: position, 32 bit floating decimal point format
For S400/S600 only. With this object the target position for motion task 0 (direct motion task, see
ASCII – command O_P) can be set in 32 Bit Floating decimal point format (IEEE).
Right of decimal point positions will be truncated. This objekt is, aside from the data format, identi-
cal PNU 1790. The defaults are indicated in micrometers.
Use:
Controls that support only 16 Bit integer and 32 Bit floating decimal point.
4.2.5.12
PNU 1312: velocity, 32 bit floating decimal point format
For S400/S600 only. With this object the velocity for motion task 0 (direct motion task, see ASCII –
command O_V) can be set in 32 Bit Floating decimal point format (IEEE).
Right of decimal point positions will be truncated. This objekt is, aside from the data format, identi-
cal PNU 1791.
Use:
Controls that support only 16 Bit integer and 32 Bit floating decimal point.
30
04/2017
PROFIBUS for S300/S400/S600/S700
Kollmorgen