Changes To The B30 Manual - GE UR Series B30 Instruction Manual

Bus differential system
Hide thumbs Also See for UR Series B30:
Table of Contents

Advertisement

F.1 CHANGE NOTES
Table F–2: MAJOR UPDATES FOR B30 MANUAL REVISION W2
PAGE
PAGE
CHANGE
(W1)
(W2)
Title
Title
Update
---
---
Update
---
---
Update
---
xiii
Add
---
---
Add
---
---
Add
1-1
1-1
Update
2-
2-
Update
3-10
3-10
Update
3-18
3-18
Update
3-24
3-24
Update
3-24
3-24
Update
3-27
3-27
Update
4-23
4-23
Delete
5-91
5-91
Update
F
A-
A-
Update
B-
B-
Update
F-12
F-12
Update
Table F–3: MAJOR UPDATES FOR B30 MANUAL REVISION W1 (Sheet 1 of 2)
PAGE
PAGE
CHANGE
(V2)
(W1)
Title
Title
Update
2-10
2-10
Update
2-17
2-17
Update
4-3
4-3
Update
5-20
5-20
Update
5-38
5-40
Update
5-51
5-53
Update
5-68
5-70
Update
5-72
5-74
Update
5-85
5-87
Update
---
5-157
Add
5-161
5-167
Update
F-2
DESCRIPTION
Updated manual part number to 1601-0109-W2
Updated safety symbols throughout document
Updated number of elements throughout document
Added battery disposal information as chapter 0
Added the 10/100Base-T connection to CPU modules 9J and 9K as of November 2014 (product
change)
Added EAC compliance information throughout, including logo on title page, rear panel, added
specifications, added life expectancy and decommissioning, added sections on Uninstall and
Clear Files and Data, Repairs, Storage, and Disposal
Updated technical support contact information
Updated order codes
Updated Figure 3-12 Typical Wiring Diagram to include delta and wye voltage input options
Updated Figure 3-17 Contact Input and Output Module Wiring to include surge on module 67
Updated section 3.2.9 CPU Communication Ports section
Updated RS485 PORTS section
Updated Figure 3-26 Options for IRIG-B Connection
Deleted Standard Faceplate section on how to customize LED and blank panels. Clear Lexan
front cover (part number 1501-0014) no longer being sold. Units with blank LED panels no longer
being sold.
Updated FlexLogic operands table
Updated FlexAnalog table
Updated Modbus memory map and F codes
Updated product warranty from 24 months to 10 years
DESCRIPTION
Manual part number to 1601-0109-W1
Updated PROTECTION ELEMENTS specifications section
Updated TYPE TESTS specifications section
Updated USING SETTING FILES section
Updated IEC 61850 PROTOCOL section
Updated OSCILLOGRAPHY section
Updated USER-DEFINABLE DISPLAYS section
Updated BREAKERS section
Updated DISCONNECT SWITCHES section
Updated FLEXLOGIC™ OPERANDS table
Added THERMAL OVERLOAD PROTECTION section
Updated REMOTE INPUTS section
B30 Bus Differential System
APPENDIX F
F.1.2 CHANGES TO THE B30 MANUAL
GE Multilin