GE UR Series B30 Instruction Manual page 414

Bus differential system
Hide thumbs Also See for UR Series B30:
Table of Contents

Advertisement

B.4 MEMORY MAPPING
Table B–10: MODBUS MEMORY MAP (Sheet 6 of 51)
ADDR
REGISTER NAME
21AC
Breaker Flashover 1 Voltage Pickup Level
21AD
Breaker Flashover 1 Voltage Difference Pickup Level
21AF
Breaker Flashover 1 Current Pickup Level
21B0
Breaker Flashover 1 Pickup Delay
21B1
Breaker Flashover 1 Supervision Phase A
B
21B2
Breaker Flashover 1 Supervision Phase B
21B3
Breaker Flashover 1 Supervision Phase C
21B4
Breaker Flashover 1 Block
21B5
Breaker Flashover 1 Events
21B6
Breaker Flashover 1 Target
21B7
Reserved (4 items)
21BB
...Repeated for Breaker Flashover 2
Passwords Unauthorized Access (Read/Write Command)
2230
Reset Unauthorized Access
Filed Unit Raw Data Settings (Read/Write Setting)
2460
Field Raw Data Port
2461
Filed Raw Data Freeze
Bus Actuals (Read Only) (2 modules)
2500
Bus Differential IA Magnitude
2502
Bus Differential IA Angle
2503
Bus Differential IB Magnitude
2505
Bus Differential IB Angle
2506
Bus Differential IC Magnitude
2508
Bus Differential IC Angle
2509
Bus Differential Rest IA Magnitude
250B
Bus Differential Rest IA Angle
250C
Bus Differential Rest IB Magnitude
250E
Bus Differential Rest IB Angle
250F
Bus Differential Rest IC Magnitude
2511
Bus Differential Rest IC Angle
2515
Bus Maximum CT Primary
2517
Reserved (9 items)
2520
...Repeated for Bus 2
Remote Double-Point Status Inputs (Read/Write Setting Registers) (5 modules)
2620
Remote Double-Point Status Input 1 Device
2621
Remote Double-Point Status Input 1 Item
2622
Remote Double-Point Status Input 1 Name
2628
Remote Double-Point Status Input 1 Events
2629
... Repeated for Double-Point Status Input 2
2632
... Repeated for Double-Point Status Input 3
263B
... Repeated for Double-Point Status Input 4
2644
... Repeated for Double-Point Status Input 5
IEC 61850 GGIO5 Configuration (Read/Write Setting Registers) (16 modules)
26B0
IEC 61850 GGIO5 uinteger Input 1 Operand
26B1
IEC 61850 GGIO5 uinteger Input 2 Operand
26B2
IEC 61850 GGIO5 uinteger Input 3 Operand
26B3
IEC 61850 GGIO5 uinteger Input 4 Operand
26B4
IEC 61850 GGIO5 uinteger Input 5 Operand
26B5
IEC 61850 GGIO5 uinteger Input 6 Operand
26B6
IEC 61850 GGIO5 uinteger Input 7 Operand
26B7
IEC 61850 GGIO5 uinteger Input 8 Operand
26B8
IEC 61850 GGIO5 uinteger Input 9 Operand
26B9
IEC 61850 GGIO5 uinteger Input 10 Operand
26BA
IEC 61850 GGIO5 uinteger Input 11 Operand
B-14
RANGE
0 to 1.5
0 to 100000
0 to 1.5
0 to 65.535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 1
0 to 2
---
0 to 1
0 to 7
0 to 1
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 50000
---
1 to 32
0 to 64
1 to 64
0 to 1
---
---
---
---
---
---
---
---
---
---
---
B30 Bus Differential System
APPENDIX B
UNITS
STEP
FORMAT
pu
0.001
F001
V
1
F060
pu
0.001
F001
s
0.001
F001
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F102
---
1
F109
---
---
F001
---
1
F126
---
1
F244
---
1
F102
A
0.001
F060
degrees
0.1
F002
A
0.001
F060
degrees
0.1
F002
A
0.001
F060
degrees
0.1
F002
A
0.001
F060
degrees
0.1
F002
A
0.001
F060
degrees
0.1
F002
A
0.001
F060
degrees
0.1
F002
---
1
F060
---
---
F001
---
1
F001
---
1
F606
---
1
F205
---
1
F102
---
---
F612
---
---
F612
---
---
F612
---
---
F612
---
---
F612
---
---
F612
---
---
F612
---
---
F612
---
---
F612
---
---
F612
---
---
F612
DEFAULT
850
1000
600
100
0
0
0
0
0 (Disabled)
0 (Self-Reset)
0
0 (No)
6 (H1a)
0 (Disabled)
0
0
0
0
0
0
0
0
0
0
0
0
1
0
1
0 (None)
"RemDPS Ip 1"
0 (Disabled)
0
0
0
0
0
0
0
0
0
0
0