GE UR Series B30 Instruction Manual page 458

Bus differential system
Hide thumbs Also See for UR Series B30:
Table of Contents

Advertisement

B.4 MEMORY MAPPING
Table B–10: MODBUS MEMORY MAP (Sheet 50 of 51)
ADDR
REGISTER NAME
D314
...Repeated for Remote Output 30
D318
...Repeated for Remote Output 31
D31C
...Repeated for Remote Output 32
IEC 61850 GGIO2 Control Configuration (Read/Write Setting) (64 modules)
D320
IEC 61850 GGIO2.CF.SPCSO1.ctlModel Value
B
D321
IEC 61850 GGIO2.CF.SPCSO2.ctlModel Value
D322
IEC 61850 GGIO2.CF.SPCSO3.ctlModel Value
D323
IEC 61850 GGIO2.CF.SPCSO4.ctlModel Value
D324
IEC 61850 GGIO2.CF.SPCSO5.ctlModel Value
D325
IEC 61850 GGIO2.CF.SPCSO6.ctlModel Value
D326
IEC 61850 GGIO2.CF.SPCSO7.ctlModel Value
D327
IEC 61850 GGIO2.CF.SPCSO8.ctlModel Value
D328
IEC 61850 GGIO2.CF.SPCSO9.ctlModel Value
D329
IEC 61850 GGIO2.CF.SPCSO10.ctlModel Value
D32A
IEC 61850 GGIO2.CF.SPCSO11.ctlModel Value
D32B
IEC 61850 GGIO2.CF.SPCSO12.ctlModel Value
D32C
IEC 61850 GGIO2.CF.SPCSO13.ctlModel Value
D32D
IEC 61850 GGIO2.CF.SPCSO14.ctlModel Value
D32E
IEC 61850 GGIO2.CF.SPCSO15.ctlModel Value
D32F
IEC 61850 GGIO2.CF.SPCSO16.ctlModel Value
D330
IEC 61850 GGIO2.CF.SPCSO17.ctlModel Value
D331
IEC 61850 GGIO2.CF.SPCSO18.ctlModel Value
D332
IEC 61850 GGIO2.CF.SPCSO19.ctlModel Value
D333
IEC 61850 GGIO2.CF.SPCSO20.ctlModel Value
D334
IEC 61850 GGIO2.CF.SPCSO21.ctlModel Value
D335
IEC 61850 GGIO2.CF.SPCSO22.ctlModel Value
D336
IEC 61850 GGIO2.CF.SPCSO23.ctlModel Value
D337
IEC 61850 GGIO2.CF.SPCSO24.ctlModel Value
D338
IEC 61850 GGIO2.CF.SPCSO25.ctlModel Value
D339
IEC 61850 GGIO2.CF.SPCSO26.ctlModel Value
D33A
IEC 61850 GGIO2.CF.SPCSO27.ctlModel Value
D33B
IEC 61850 GGIO2.CF.SPCSO28.ctlModel Value
D33C
IEC 61850 GGIO2.CF.SPCSO29.ctlModel Value
D33D
IEC 61850 GGIO2.CF.SPCSO30.ctlModel Value
D33E
IEC 61850 GGIO2.CF.SPCSO31.ctlModel Value
D33F
IEC 61850 GGIO2.CF.SPCSO32.ctlModel Value
D340
IEC 61850 GGIO2.CF.SPCSO33.ctlModel Value
D341
IEC 61850 GGIO2.CF.SPCSO34.ctlModel Value
D342
IEC 61850 GGIO2.CF.SPCSO35.ctlModel Value
D343
IEC 61850 GGIO2.CF.SPCSO36.ctlModel Value
D344
IEC 61850 GGIO2.CF.SPCSO37.ctlModel Value
D345
IEC 61850 GGIO2.CF.SPCSO38.ctlModel Value
D346
IEC 61850 GGIO2.CF.SPCSO39.ctlModel Value
D347
IEC 61850 GGIO2.CF.SPCSO40.ctlModel Value
D348
IEC 61850 GGIO2.CF.SPCSO41.ctlModel Value
D349
IEC 61850 GGIO2.CF.SPCSO42.ctlModel Value
D34A
IEC 61850 GGIO2.CF.SPCSO43.ctlModel Value
D34B
IEC 61850 GGIO2.CF.SPCSO44.ctlModel Value
D34C
IEC 61850 GGIO2.CF.SPCSO45.ctlModel Value
D34D
IEC 61850 GGIO2.CF.SPCSO46.ctlModel Value
D34E
IEC 61850 GGIO2.CF.SPCSO47.ctlModel Value
D34F
IEC 61850 GGIO2.CF.SPCSO48.ctlModel Value
D350
IEC 61850 GGIO2.CF.SPCSO49.ctlModel Value
D351
IEC 61850 GGIO2.CF.SPCSO50.ctlModel Value
B-58
RANGE
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
B30 Bus Differential System
APPENDIX B
UNITS
STEP
FORMAT
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
DEFAULT
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
GE Multilin

Advertisement

Table of Contents
loading

Table of Contents