B.4 MEMORY MAPPING
Table B–10: MODBUS MEMORY MAP (Sheet 24 of 51)
ADDR
REGISTER NAME
65A3
CT Trouble 1 Target
65A4
CT Trouble 1 Events
65A5
...Repeated for CT Trouble 2
65AA
...Repeated for CT Trouble 3
65AF
...Repeated for CT Trouble 4
B
Phase Undervoltage (Read/Write Grouped Setting) (3 modules)
7000
Phase Undervoltage 1 Function
7001
Phase Undervoltage 1 Signal Source
7002
Phase Undervoltage 1 Pickup
7003
Phase Undervoltage 1 Curve
7004
Phase Undervoltage 1 Delay
7005
Phase Undervoltage 1 Minimum Voltage
7006
Phase Undervoltage 1 Block
7007
Phase Undervoltage 1 Target
7008
Phase Undervoltage 1 Events
7009
Phase Undervoltage 1 Measurement Mode
700A
Reserved (6 items)
7013
...Repeated for Phase Undervoltage 2
7020
...Repeated for Phase Undervoltage 3
DCmA Inputs (Read/Write Setting) (24 modules)
7300
DCmA Inputs 1 Function
7301
DCmA Inputs 1 ID
7307
Reserved 1 (4 items)
730B
DCmA Inputs 1 Units
730E
DCmA Inputs 1 Range
730F
DCmA Inputs 1 Minimum Value
7311
DCmA Inputs 1 Maximum Value
7313
Reserved (5 items)
7318
...Repeated for DCmA Inputs 2
7330
...Repeated for DCmA Inputs 3
7348
...Repeated for DCmA Inputs 4
7360
...Repeated for DCmA Inputs 5
7378
...Repeated for DCmA Inputs 6
7390
...Repeated for DCmA Inputs 7
73A8
...Repeated for DCmA Inputs 8
73C0
...Repeated for DCmA Inputs 9
73D8
...Repeated for DCmA Inputs 10
73F0
...Repeated for DCmA Inputs 11
7408
...Repeated for DCmA Inputs 12
7420
...Repeated for DCmA Inputs 13
7438
...Repeated for DCmA Inputs 14
7450
...Repeated for DCmA Inputs 15
7468
...Repeated for DCmA Inputs 16
7480
...Repeated for DCmA Inputs 17
7498
...Repeated for DCmA Inputs 18
74B0
...Repeated for DCmA Inputs 19
74C8
...Repeated for DCmA Inputs 20
74E0
...Repeated for DCmA Inputs 21
74F8
...Repeated for DCmA Inputs 22
7510
...Repeated for DCmA Inputs 23
7528
...Repeated for DCmA Inputs 24
Disconnect (Breaker) Switch (Read/Write Setting) (24 modules)
7540
Disconnect Switch 1 Function
7541
Disconnect Switch 1 Name
B-32
RANGE
0 to 2
0 to 1
0 to 1
0 to 5
0 to 3
0 to 1
0 to 600
0 to 3
0 to 65535
0 to 2
0 to 1
0 to 1
0 to 1
0 to 1
---
0 to 65535
---
0 to 6
-9999.999 to 9999.999
-9999.999 to 9999.999
0 to 65535
0 to 1
---
B30 Bus Differential System
APPENDIX B
UNITS
STEP
FORMAT
---
1
F109
---
1
F102
---
1
F102
---
1
F167
pu
0.001
F001
---
1
F111
s
0.01
F001
pu
0.001
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F186
0 (Phase to Ground)
---
1
F001
---
1
F102
---
---
F205
---
1
F001
---
---
F206
---
1
F173
---
0.001
F004
---
0.001
F004
---
1
F001
---
1
F102
---
---
F206
DEFAULT
0 (Self-reset)
0 (Disabled)
0 (Disabled)
0 (SRC 1)
1000
0 (Definite Time)
100
100
0
0 (Self-reset)
0 (Disabled)
0
0 (Disabled)
"DCmA Ip 1"
0
"mA"
6 (4 to 20 mA)
4000
20000
0
0 (Disabled)
"SW 1"
GE Multilin