Pwbs; Detaching And Refitting The Control Pwb - Kyocera KM-2810 Service Manual

Hide thumbs Also See for KM-2810:
Table of Contents

Advertisement

1-5-9

PWBs

(1) Detaching and refitting the control PWB

Procedure
1. Remove the right cover (See page 1-5-3).
2. Remove the five connectors from the scan-
ner PWB.
3. Remove twenty one connectors and two
FFCs form the control PWB.
4. Remove the wires from the clamp.
Connectors
Scanner PWB
Control PWB
(FFC)
YC6
YC28
YC29
Connectors
Figure 1-5-50
YC104
YC108
YC105
Scanner PWB
Wires
Control PWB
Clamp
(FFC)
YC7
YC3
YC8
FFCs
2H9
YC109
YC101
YC19
1-5-35