4. Remove two screws.
5. Unhook three hooks and then remove the
original holder cover.
6. Move the image scanner unit (ISU) unit to
the center.
7. Detach the ISU shaft from the holder by lift-
ing it.
8. Remove the FFC.
Original holder cover
Hooks
Holder
Image scanner
unit (ISU)
Screw
Figure 1-5-28
ISU shaft
Figure 1-5-29
2H9
Screw
FFC
1-5-21