Kyocera KM-2810 Service Manual page 70

Hide thumbs Also See for KM-2810:
Table of Contents

Advertisement

2H9
Maintenance
item No.
Checking the copy counts
U920
Description
Checks the copy counts.
Purpose
To check the copy counts.
Method
Press the start key. The current counts of copy counter, printer counter and fax counter are displayed.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Clearing the all copy counts and machine life counts (one time only)
U927
Description
Resets all of the counts back to 0.
Purpose
To start the counters with value 0 when installing the machine.
Supplement
The total account counter and the machine life counter can be cleared only once if all count values are 1000
or less.
Method
1. Press the start key.
2. Select EXECUTE.
3. Press the start key. All copy counts and machine life counts are cleared.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Checking machine life counts
U928
Description
Displays the machine life counts.
Purpose
To check the machine life counts.
Method
1. Press the start key. The current machine life counts is displayed.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Setting of deflection for feeding from DP
U942
Description
Adjusts the deflection generated when the optional DP is used.
Purpose
Use this mode if an original non-feed jam, oblique feed or wrinkling of original occurs when the DP is used.
Setting
1. Press the start key.
2. Select the item to be adjusted.
Display
REGIST TOP
REGIST
BACK
3. Press the system menu key.
4. Place an original on the DP and press the start key to make a test copy.
5. Press the system menu key.
6. Change the setting value using the cursor left/right keys.
The greater the value, the larger the deflection; the smaller the value, the smaller the deflection.
If an original non-feed jam or oblique feed occurs, increase the setting value. If wrinkling of original
occurs, decrease the value.
7. Press the start key. The setting is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
1-3-46
Description
Deflection of single-sided original
Deflection of double-sided original
Description
Setting
range
-31 to 31
-31 to 31
Initial
Change in
setting
value per step
0
0.098 mm
0
0.098 mm

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents