Maintenance
item No.
Setting backup data reading/writing
U917
Description
Retrieves the backup data to a USB memory from the machine; or writes the data from the USB memory to
the machine.
Purpose
To store and write data when replacing the control PWB.
Method
1. Press the power key on the operation panel, and after verifying the power indicator has gone off, switch
off the main power switch.
2. Insert USB memory in USB memory slot.
3. Turn the main power switch on.
4. Enter the maintenance item.
5. Press the start key.
6. Select [Export] or [Import].
Display
IMPORT
EXPORT
7. Select the item using the cursor left/right keys.
Display
ADDRESS BOOK
JOB ACCNT.
ONE TOUCH
USER
PROGRAM
DOCUMENT BOX
*: Since data are dependent with each other, data other than those assigned are also retrieved or written
in.
8. Select ON using the cursor left/right keys.
Wait for 10 seconds before pressing the Start key to allow the machine to recognize the USB memory.
9. Press the start key. Starts reading or writing.
The progress of selected item is displayed in%.
When an error occurs, the operation is canceled and an error code is displayed.
10. When normally completed, [FIN] is displayed.
11. Turn the main power switch off and on after completing writing when selecting IMPORT.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Description
Description
Writing data from the USB memory to the machine
Retrieving from the machine to a USB memory
Description
Address book
Job accounting
Information on one-touch
User managements
Program information
Document box information Job accountings and user managements
Description
-
-
Address book
Job accounting
Job accountings and user managements