2H9
Code
3200
Exposure lamp error
The exposure lamp is not turned on.
3300
AGC error
After AGC, correct input is not obtained
at CCD.
1-4-6
Contents
Causes
Check procedures/corrective measures
Defective FFC
Reinsert the FFC. Also check for continuity
between scanner
within the FFC. If none, remedy or replace
PWB (YC103) and
the FFC.
control PWB
(YC6), or improper
FFC insertion.
Defective FFC
Reinsert the FFC. Also check for continuity
between control
within the FFC. If none, remedy or replace
PWB (YC8) and
the FFC.
CCD PWB (YC1),
or improper FFC
insertion.
Defective harness
Reinsert the connector. Also check for conti-
between CCD
nuity within the connector harness. If none,
PWB (YC3) and
remedy or replace the harness.
inverter PWB
(YC101), or
improper connec-
tor insertion.
Defective harness
Reinsert the connector. Also check for conti-
between inverter
nuity within the connector harness. If none,
PWB (YC102) and
remedy or replace the harness.
exposure lamp, or
improper connec-
tor insertion.
Defective exposure
Replace the exposure lamp (See page 1-5-
lamp.
23).
Defective inverter
Replace the inverter PWB (See page 1-5-
PWB.
23).
Defective control
Replace the control PWB (See page 1-5-
PWB.
35).
Defective FFC
Reinsert the FFC. Also check for continuity
between control
within the FFC. If none, remedy or replace
PWB (YC8) and
the FFC.
CCD PWB (YC1),
or improper FFC
insertion.
Defective exposure
Replace the exposure lamp (See page 1-5-
lamp.
23).
Defective CCD
Replace the CCD PWB.
PWB.
Defective control
Replace the control PWB (See page 1-5-
PWB.
35).
Remarks