Kyocera KM-2810 Service Manual page 164

Hide thumbs Also See for KM-2810:
Table of Contents

Advertisement

2H9
Connector
Pin
YC101
1
NEUTRAL
Connected
to the AC
2
LIVE
inlet
YC102
1
LIVE
Connected
to the fuser
2
NEUTRAL
heater lamp
YC103
1
+24V1
Connected
2
SGND
to the high
3
FAN
voltage
4
THERM
PWB
5
+3.3V1
6
HEATN
7
SLEEP
8
ZCROSS
9
+24V2
10
+24V2
11
PGND
12
PGND
YC104
1
+24V1
Connected
2
FAN
to the left
cooling fan
motor
YC105
1
+3.3V1
Connected
2
N.C.
to the fuser
3
THERM
thermistor
YC106
1
+24V1
Connected
2
N.C.
to the scan-
3
GND
ner PWB
YC107
1
+24V1
Connected
2
FAN
to the power
source fan
motor
YC108
1
-
Connected
2
N.C.
to the
3
-
ground ter-
minals
2-3-2
Signal
I/O
I
120 V AC
220 - 240 V AC
I
120 V AC
220 - 240 V AC
O
120 V AC
220 - 240 V AC
O
120 V AC
220 - 240 V AC
O
24 V DC
-
-
I
0/24 V DC
O
Analog
I
3.3 V DC
I
0/3.3 V DC
I
0/3.3 V DC
O
0/3.3 V DC (pulse) Zero cross signal
O
24 V DC
O
24 V DC
-
-
-
-
O
24 V DC
O
0/24 V DC
O
3.3 V DC
-
-
I
Analog
O
24 V DC
-
-
-
-
O
24 V DC
O
0/24 V DC
-
-
-
-
-
-
Voltage
AC power input
AC power input
Fuser heater lamp output
Fuser heater lamp output
24 V DC power source
Ground
Left cooling fan motor: On/Off
Fuser thermistor detection voltage
3.3 V DC power source
Fuser heater lamp: On/Off
Sleep mode signal: On/Off
24 V DC power source (via interlock switch)
24 V DC power source (via interlock switch)
Ground
Ground
24 V DC power source
Left cooling fan motor: On/Off
3.3 V DC power source
Not used
Fuser thermistor detection voltage
24 V DC power source
Not used
Ground
24 V DC power source
Power source fan motor: On/Off
Frame ground (Control PWB)
Not used
Frame ground (Frame)
Description

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents