Kyocera KM-2810 Service Manual page 64

Hide thumbs Also See for KM-2810:
Table of Contents

Advertisement

2H9
Maintenance
item No.
Adjusting the scanner automatically
U411
Description
Uses a specified original and automatically adjusts the following items in the scanner and the DP scanning
sections.
Purpose
To perform automatic adjustment of various items in the scanner and the DP scanning sections.
Method
1. Press the start key.
Display
ADJUST TABLE
ADJUST DP
Method: TABLE
1. Enter the target values which are shown on the specified original (P/N: 302FZ56990) executing mainte-
nance item U425.
2. Set a specified original (P/N: 302FZ56990) on the platen.
3. Enter maintenance item U411.
4. Select ADJUST TABLE.
5. Press the start key. Auto adjustment starts.
When automatic adjustment has normally completed, [OK] is displayed. If a problem occurs during auto
adjustment, [NG XX] (XX is replaced by an error code) is displayed and operation stops. Should this
happen, determine the details of the problem and either repeat the procedure from the beginning, or
adjust the remaining items manually by running the corresponding maintenance items.
6. To return to the screen for selecting an item, press the stop key.
Method: DP
1. Select ADJUST DP.
2. Set a specified original (P/N: 302AC68243) in the DP. Cut the trailing edge of the original.
3. Press the start key. Auto adjustment starts.
When automatic adjustment has normally completed, [OK] is displayed. If a problem occurs during auto
adjustment, [NG XX] (XX is replaced by an error code) is displayed and operation stops. Should this
happen, determine the details of the problem and either repeat the procedure from the beginning, or
adjust the remaining items manually by running the corresponding maintenance items.
4. To return to the screen for selecting an item, press the stop key.
Completion
Press the stop key. The screen for selecting a maintenance item is displayed.
1-3-40
Description
Automatic adjustment in the scanner section:
Original size magnification, leading edge timing,
center line, input gamma, input gamma, input
gamma in monochrome mode and matrix
Automatic adjustment in the DP scanning section:
Original size magnification, leading edge timing,
center line
F
R
Description
74 ± 1 mm
Figure 1-3-17
Original to be used
for adjustment (P/N)
302FZ56990
302AC68243
5 mm
149 ± 1 mm

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents