11. LV Standard Data Input
Adjust the normal coefficient of the light value at 3200K.
Adjustment Page
Adjustment Address
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 0, address: 10, and set data: 06.
3) Input the following data to page: D (6D), address: 5C and 5D.
Note: Press the PAUSE (Write) button of the adjustment remote com-
mander each time to set data.
Address
Data
5C
36
5D
10
4) Select page: 0, address: 10, and set data: 00.
5) Select page: 0, address: 01, and set data: 00.
HVR-S270J/S270U/S270N/S270E/S270P/S270C
RadarW
RadarW
RadarW
RadarW
RadarW
6D
5C, 5D
12. STD GAIN Adjustment
Correct a variation in the CMOS sensitivity setting.
As the CMOS sensitivity is dominant on the variation, correct it
with the AGC_GAIN standard setting.
Adjustment Page
Adjustment Address
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 0, address: 10, and set data: 06.
3) Input the following data to page: D (6D), address: 5A, 5E and
5F.
Note: Press the PAUSE (Write) button of the adjustment remote com-
mander each time to set data.
Address
Data
5A
00
5E
0B
5F
86
4) Select page: 0, address: 10, and set data: 00.
5) Select page: 0, address: 01, and set data: 00.
6-43
RadarW
RadarW
RadarW
RadarW
RadarW
6D
5A, 5E, 5F