Sony HVR-S270J Service Manual page 260

Digital hd video camera recorder
Table of Contents

Advertisement

3. ND Filter Switch Adjustment
Adjust a variation in AD value of the ND filter switch.
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified value
Note 1: If reading/writing data on pages 6F, set data: 06 to page:
0, address: 10, and then select pages: F. By this data set-
ting, the pages 6F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to "00".
Note 2: Perform this adjustment only when replacing the lens
block. When the microprocessor, circuit etc. is damaged,
don't perform this adjustment but check the steady shot
operations only.
Note 3: With the lens not mounted, adjust the ND filter switch
while checking visually that the ND filter is surely
switched (free from incomplete engagement).
Switch setting
1) POWER ......................................................... CAMERA mode
HVR-S270J/S270U/S270N/S270E/S270P/S270C
RadarW
RadarW
RadarW
Not required
Adjusting remote commander
6F
5C to 5F
Data of page: 6 address: D1 is "01"
Adjusting method:
Order Page Address Data
1
0
01
2
6
07
3
6
02
4
5
6
D0
6
6
01
7
6
02
8
6
D1
9
6
01
10
11
6
D0
12
6
01
13
6
02
14
6
D1
15
6
01
16
17
6
D0
18
6
01
19
6
02
20
6
D1
21
6
01
22
23
6
D0
24
6
01
25
6
02
26
6
D1
27
6
01
28
0
01
Note 4: The adjustment data will be automatically input to page:
6F, address: 5C to 5F.
Note 5: Adjustment error occurs if the data of page: 6, address:
D1 is "02".
6-26
Procedure
01
Check the data is "04".
Check the data is "00".
Set the ND FILTER to "1".
01
Press PAUSE (Write) button.
F1
(Note 4)
Check the data changes to
"01".
Check the data is "01".
(Note 5)
00
Press PAUSE (Write) button.
Set the ND FILTER to "2".
02
Press PAUSE (Write) button.
F1
(Note 4)
Check the data changes to
"01".
Check the data is "01".
(Note 5)
00
Press PAUSE (Write) button.
Set the ND FILTER to "3".
03
Press PAUSE (Write) button.
F1
(Note 4)
Check the data changes to
"01".
Check the data is "01".
(Note 5)
00
Press PAUSE (Write) button.
Set the ND FILTER to "4".
04
Press PAUSE (Write) button.
F1
(Note 4)
Check the data changes to
"01".
Check the data is "01".
(Note 5)
00
Press PAUSE (Write) button.
00