Sony HVR-S270J Service Manual page 282

Digital hd video camera recorder
Table of Contents

Advertisement

17. Auto White Balance Standard Data Input
(ND2)
RadarW
RadarW
RadarW
RadarW
RadarW
Adjust the white balance reference at 3200K, and adjust the nor-
mal coefficient of the light value.
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Note 1: Perform "Auto White Balance Standard Data Input (ND1
(CLR))" before this adjustment.
Note 2: If reading/writing data on pages 6F, set data: 06 to page:
0, address: 10, and then select pages: F. By this data set-
ting, the pages 6F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to "00".
Note 3: Check that the data of page: 6, address: 02 is "00". If
not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Switch setting
1) POWER ......................................................... CAMERA mode
2) ND FILTER ............................................................................ 2
3) D.EXTENDER (Menu setting) ....................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF
5) REC FORMAT (Menu setting) ............................. HDV1080i
HVR-S270J/S270U/S270N/S270E/S270P/S270C
Clear chart (Color reproduction
adjustment frame)
Adjusting remote commander
6F
8C to 8F
Data of page: 6 address: 0C is "00"
Adjusting method:
Order Page Address Data
1
0
01
2
6
99
3
6
02
4
6
07
5
0
10
6
6
07
(16)
7
0
10
8
6
61
9
10
0
10
6
11
40
(16)
12
0
10
13
6
41
14
6
01
15
6
02
16
6
0C
Note 4: The adjustment data will be automatically input to page:
6F, address: 8C to 8F.
Processing after Completing Adjustment:
Order Page Address Data
1
6
01
2
0
10
6
3
40
(16)
4
0
10
5
6
41
6
6
61
7
8
0
01
6-48
Procedure
01
Check the data is "01".
Check the data is "00".
Check the data is "04".
01
Check the data is "04".
00
01
Wait for 3 seconds.
01
01
00
01
Press PAUSE (Write) button.
0B
(Note 4)
Check the data changes to
"01".
Check the data is "00".
Procedure
00
Press PAUSE (Write) button.
01
00
00
00
00
Wait for 3 seconds.
00