6-2. Flange Back Check (ND2)
(Using the flange back adjustment jig)
Subject
Measurement Point
Measuring Instrument
Specified value
Note 1: Check that the data of page: 0, address: 10 is "00".
Note 2: Check with the monitor larger than 40 inches.
Switch setting
1) POWER ......................................................... CAMERA mode
2) ND FILTER ............................................................................ 2
3) REC FORMAT (Menu setting) ............................. HDV1080i
Checking method:
Order Page Address Data
1
2
0
01
3
6
99
4
0
10
6
5
2C
(16)
6
6
40
(16)
7
0
10
8
6
41
9
6
4D
10
11
0
10
6
12
2C
(16)
13
14
15
Processing after Completing Adjustment:
Order Page Address Data
6
1
2C
(16)
6
2
40
(16)
3
0
10
4
6
41
5
6
4D
6
0
10
6
7
2C
(16)
8
0
10
9
0
01
HVR-S270J/S270U/S270N/S270E/S270P/S270C
Flange back adjustment jig
(Illuminance: approx. 200 ± 50 lux)
Check operation on monitor TV
(Note 2)
Focused at the TELE end and WIDE
end
Procedure
Set the ND FILTER to "2".
01
Check the data is "01".
01
01
01
00
01
40
Shoot the chart with
the zoom TELE end.
01
02
Check that the lens is
focused.
Shoot the chart with the
zoom WIDE end.
Check that the lens is
focused.
Procedure
00
00
00
00
00
01
00
00
00
6-3. Flange Back Check (ND3)
(Using the flange back adjustment jig)
Subject
Measurement Point
Measuring Instrument
Specified value
Note 1: Check that the data of page: 0, address: 10 is "00".
Note 2: Check with the monitor larger than 40 inches.
Switch setting
1) POWER ......................................................... CAMERA mode
2) ND FILTER ............................................................................ 3
3) REC FORMAT (Menu setting) ............................. HDV1080i
Checking method:
Order Page Address Data
1
2
0
01
3
6
99
4
0
10
6
5
2C
(16)
6
6
40
(16)
7
0
10
8
6
41
9
6
4D
10
11
0
10
6
12
2C
(16)
13
14
15
Processing after Completing Adjustment:
Order Page Address Data
6
1
2C
(16)
6
2
40
(16)
3
0
10
4
6
41
5
6
4D
6
0
10
6
7
2C
(16)
8
0
10
9
0
01
6-37
Flange back adjustment jig
(Illuminance: approx. 200 ± 50 lux)
Check operation on monitor TV
(Note 2)
Focused at the TELE end and WIDE
end
Procedure
Set the ND FILTER to "3".
01
Check the data is "02".
01
01
01
00
01
40
Shoot the chart with
the zoom TELE end.
01
02
Check that the lens is
focused.
Shoot the chart with the
zoom WIDE end.
Check that the lens is
focused.
Procedure
00
00
00
00
00
01
00
00
00

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hvr-s270uHvr-s270cHvr-s270nHvr-s270eHvr-s270p

Table of Contents