Tracing At Execute; Using The Analyzer Trigger To Break Into The Monitor - HP 64700 series User Manual

Emulators
Hide thumbs Also See for 64700 series:
Table of Contents

Advertisement

Tracing at
EXECUTE
Using the
Analyzer Trigger
to Break into the
Monitor
To specify that an analyzer measurement begin upon reception of the
CMB EXECUTE signal, select the following PC Interface command:
Analysis, CMB, Begin
The trace measurement defined by the current trace specification will
be started when the EXECUTE signal becomes active. When the trace
measurement begins, you will see the message "ALERT: CMB
execute; emulation trace started".
To cause emulator execution to break into the monitor when the
analyzer trigger condition is found, you must modify the trigger
configuration. To access the trigger configuration, select:
Config, Trigger
The trigger configuration display contains two diagrams, one for each
of the internal TRIG1 and TRIG2 signals.
To use the internal TRIG1 signal to connect the analyzer trigger to the
emulator break line, highlight the "Analyzer" field in the TRIG1
portion of the display, and use the Tab key to select the single-headed
arrow pointing towards TRIG1; this shows that the analyzer is driving
TRIG1.
Next, highlight the "Emulator" field and use the Tab key to select the
arrow pointing towards the emulator; this specifies that emulator
execution will break into the monitor when the TRIG1 signal is driven.
The resulting trigger configuration display is shown in figure 6-1.
Making Coordinated Measurements 6-3