YASKAWA pg-b3 Installation Manual page 28

Yaskawa ac drive 1000-series option complementary type pg
Hide thumbs Also See for pg-b3:
Table of Contents

Advertisement

6 Related Parameters
No.
Name
(Addr. Hex)
F1-31
PG 2 Pulse
(3B0)
Setting
<2> <7>
F1-32
(3B1)
PG 2 Rotation
<7>
F1-33
PG 2 Gear
(3B2)
Teeth 1
<5> <7>
F1-34
PG 2 Gear
(3B3)
Teeth 2
<5> <7>
F1-35
PG 2 Division
(3BE)
Ratio for Pulse
Monitor
<7>
F1-37
PG 2 Option
(3BD)
Function
<7>
<1> Varies by drive models.
<2> The number of output pulses for the PG encoder can be calculated with the following formula:
Motor speed at maximum frequency output (min
f
(Hz)
PG
<3> The parameter is available only for the drive connector CN5-C.
<4> Value changes according to the control mode selection in A1-02.
<5> Enabled only when using the V/f with PG control mode.
<6> Depending on the drive series, a second PG encoder (PG 2) may not be possible. Refer to the drive Technical
Manual for the drive in your application.
<7> The parameter is available only for the drive connector CN5-B.
28
Description
Sets the pulses to be read from the pulse generator.
0: Forward = A pulse leads
1: Forward = B pulse leads
Number of gear teeth between the PG and motor.
Pulses × 60
F1-33 (load side)
×
F1-31
F1-34 (motor side)
A gear ratio of 1 will be used if any of these
parameters is set to 0.
Sets the division ratio for PG encoder pulse output.
Set as a three-digit number where x is the first digit, y
is the second digit, and z is the third digit:
(1 + x)
Ratio =
yz
When only the A pulse is read, this ratio is disabled
and pulses are set as 1/32 : 1.
0: A pulse detection
1: AB pulse detection
60
YASKAWA ELECTRIC TOBP C730600 36C 1000-Series Option PG-B3 Installation Manual
Control
Mode
V/f w/ PG
CLV
V/f w/ PG
CLV
V/f w/ PG
V/f w/ PG
CLV
V/f w/ PG
-1
)
× PG rating (p/rev)
Values
Default: 1024
Min: 0
Max: 60000
Default: 0
Range: 0, 1
Default: 0
Min: 0
Max: 1000
Default: 1
Min: 1
Max: 132
Default: 0
Range: 0, 1
B3