13.8.
Heater
Pipe type heater is used in the machine. It is taken out by unscrewing the two spring clamps.
13.9.
Circulation Pump
After the clamps and cable connections of the circulation pump
are removed, the screws of the motor holding plate connected
to the body frame are unscrewed. So as to detach the
circulation pump from the motor holding plate, the connection
is cut off by breaking the white coloured auricle shown in the
photo, and a new auricle is installed during the assembly
84
BUILT- UNDER DISHWASHER