Maintenance

Only original Truma parts may be used for maintenance and
repair work.
– Even outside the season, the heater should be operated
once a month for about ten minutes.
– Clean installation area at least once per year, and have unit
checked for soiling and cleaned by an expert if necessary.
– The drain valve must be actuated regularly (at least twice
per year) in order to remove limescale deposits and to ensu-
re that it is not blocked.
Biofilm, deposits and limescale must be removed using
chemicals to protect the unit from infestation by microorgan-
isms. Only chloride-free products must be used in order to
prevent damage to the unit.
The effectiveness of the use of chemicals to combat microor-
ganisms in the unit can be increased by heating the water in
the hot water system to 70 °C at regular intervals.
– Set water temperature to 60 °C.
– Switch on unit.
Once the water in the water heater has reached a tem-
perature of 60 °C, the burner will switch off. The unit
must stay switched on for at least 30 minutes and no warm
water may be withdrawn. The residual heat in the heat ex-
changer will heat the water up to 70 °C.

Fuses

The fuses are located in the electronic control unit, beneath
the connector cover. When replacing a fuse, be sure to use
the same type.
Device fuse: 10 A – slow – 5 x 20 mm (T 10 A)
Burner fuse: 20 A – slow – 6.3 x 32 mm
Fig. 5

Disposal

The heater unit must be disposed of in accordance with the
administrative regulations of the country in which it is in use.
National regulations and laws must be observed.
T 20 A
T 10 A

Technical data

(found by Truma Test conditions)
Protection type / protection class
IP21 / class I
Fuel
Fuel, as per the Australian Fuel Standard (Automotive Diesel).
Operation with any form of biodiesel is not permitted.
Water volume
10 litres
Maximum working water pressure
500 kPa
P&T relief valve setting
500 kPa – 99 °C – 10 kW
Heating up time from approx. 15 °C to approx. 60 °C
Hot water system approx. 20 minutes (measured according to
EN 15033)
Heater + hot water system approx. 80 min.
Pump pressure
max. 280 kPa
System pressure
max. 450 kPa
Rated thermal output (automatic output levels)
2000 / 4000 / 6000 W
Fuel consumption
220 – 630 ml/h (110 ml/h during normal operation with
moderate heat output of 1000 W)
Air delivery volume (free-blowing without hot-air pipe)
max. 287 m³/h
Current input at 12 V
Heater + hot water system 1.8 – 7 A (in regular operation, be-
tween "Off" and "lowest operating level" less than 1.8 A).
Heating hot water system without operational heater, max. 1.8 A
Stand-by: approx. 0.001 A
Weight (without water)
Heater unit:
16.2 kg
Heater unit with
peripheral devices: 17.6 kg
Water pressure reducer
Flow range water: 0 – 10 litres/min.
Maximum inlet pressure:
Maximum outlet pressure: 200 kPa
E1 122R 000232
E1 10R 035277

Dimensions

450 mm
Fig. 6
The right to make technical modifications is reserved!
700 kPa
525 mm
7