Parts Replacement and Cleaning Procedure > Consumable Parts and Cleaning Points > Removing the Stitcher Unit
Removing the Stitcher Unit
NOTE:
When replacing the consumable parts, be sure to clear the parts counter.
(COPIER > COUNTER > DRBL-2 > SDL-STPL)
1) Open the front cover.
2) Pull out the stitcher mount unit to the front, then pull out the stitcher towards yourself and
then pull up the stitcher.
3) Remove three screws [2] and remove the stitcher cover [3].
[3]
4
Parts Replacement and Cleaning Procedure > Consumable Parts and Cleaning Points > Removing the Stitcher Unit
[2]
[1]
F-4-72
4) Remove the connector [1].
5) Remove three screws [2] and remove the stitcher unit [3].
[1]
[3]
[2]
4-35
[3]
[2]
F-4-73
4-35