Appendix 1
Mechanical ICD Reference
VIsible Camera
Spotlight
Infrared
Camera
2.52
64.1
8.86
225.0 min base plate diameter
for effective o-ring seal
Cable port dimensions depend on
Mounting solution and cable type.
AS568A-436 EPDM O-Ring
[5.85in ID x .275in DIA]
149mm ID x 7mm DIA
AS658A-444 EPDM O-Ring
[7.72in ID x .275in DIA]
196mm ID x 7mm DIA
HD/SDI BNC connector
Ethernet connector
Clearance required for free motion of system.
12.34
313.5
9.35
237.5
5.34
135.7
10.75
273.1
6X M6X1.0
10
Warning
Do not bottom fasteners in base.
Bolt length not to exceed 6mm into base.
Electronics will be damaged by base penetration - voiding warranty.
Bolt torque not to exceed 9.5N-m (7 lb-ft).
Use Loctite 262 with all metal to metal threaded connections
that do not have locking patches.
7.09
180.0 bolt circle
Power connector
Analog video and serial connector
Warranty void if screws removed
M400 Installation Guide
15.65
397.6
5.87
149.1
432-0012-00-12, version 110
Clearance required for free motion of system.
9.61
244.2
O-Ring used for sealing system to mounting structure.
Stand alone unit meets IPx6 sealing specification.
Minimum mounting surface flatness of 1.5mm [0.060in]
over system diameter required for o-ring use. When
mounting to irregular surfaces, use of bedding compound
is recommended.
All dimensions are in mm and (inches)