display on the LCD. If the rotary switches are set to '04' the information for endpoint node '04 will be
displayed. The gateway can only display device information if they are defined with Modbus registers.
The LCD will display any system warnings or errors, any device warnings or errors and the state of
each I/O point defined for that device. The LCD display will continuously cycle through this information
until the rotary switches change or a button change is detected.
Device Information (LCD display = 'DEVINF') From the Run mode state, single click button 1 to get
to the Device Information selection. Single click button 2 will begin displaying the information for the
device defined by the rotary switches. The LCD will display 'NAME A', 'NAME B', 'NAME C', RF
Message and Device warnings / errors.
The NAME A, B and C fields are a user defined name that can be associated with each device. A total
of 18 characters can be used. The name fields can be defined under the CONFIG menu.
The RF message can be one of several informational messages about the RF link between the gateway
and node. 'NO RF', 'RF OFF', 'RF SYNC' and 'RF OK' are the RF messages. 'NO RF' indicates there is
no communication link between the device defined by the rotary switches and the gateway. 'RF OFF'
indicates the device has been disabled. 'RF SYNC' indicates that the node and the gateway are in the
process of trying to synchronize communications. All devices should synchronize within 20 seconds of
being enabled. 'RF OK' indicates the wireless communications between the gateway and node are
operating normally.
The device warnings and error messages displayed will be for the device defined by the rotary
switches. See the 'Warnings & Error Messages' section for full explanations of each message.
To exit the device information state, double click button 2
Factory Settings (LCD display = 'FACTRY') From the run mode state, single click button 1 and then
single click button 1 again to arrive at the factory settings display. To begin the cycle through the factory
information display single click button 2. The display information will include: serial number, model
number, software version for the RF processor, software version for the communications processor and the
production date.
To exit the factory settings state, double click button 2.