4.2 WF-2000 series Configuration

4.2.1 WF-2000 Series Wireless Network Configuration

01、Net ID : The Unit Identifier in Modbus TCP/IP application data
unit. This case is set as "1" in Figure 4-3.
02、IP Address : Set the local WF-2000 series' IP. Here set to
"192.168.255.1".
03、Subnet Mask : Net Mask settings. Here set to "255.255.0.0".
04、Gateway : Gateway settings. Here set to "192.168.255.254".
05、DHCP Server Enable : Enable DHCP Server.
06、Start IP Addr. : The client IP address starts from the configured
static IP address. Here set to "192.168.255.100".
07、Wi-Fi Mode : Wireless network connection mode settings. Here
set to "Limited AP" mode. (If select the "Limited AP" mode, the
"DHCP Server" function is enabled)
08、SSID : Service set identifier. Here set to "WF-20xx".
09、Encryption : Encryption mode settings. Here set "NONE" (without
encryption).
10、Wireless Key : Wireless encryption Key. Here does not have the
setting.
11、Wireless CH : Wi-Fi connection channel settings. Here set to "2".
12、Upload parameters : After completing the settings above, select
the "RS-232" interface, communication "Net ID" and "COM Num".
Press "Write Parameter" button to upload the parameters.
WF-2000 Series DIO
Figure 4-3: Configuration Interface