GE B90 UR Series Instruction Manual page 329

Low impedance bus differential system
Hide thumbs Also See for B90 UR Series:
Table of Contents

Advertisement

APPENDIX B
Table B–9: MODBUS MEMORY MAP (Sheet 6 of 48)
ADDR
REGISTER NAME
Security (Read/Write Setting)
32BF
Operator alphanumeric password setting
Security (Read Only)
32C9
Operator alphanumeric password status
Security (Read/Write)
32CA
Operator alphanumeric password entry
Security (Read/Write Setting)
32D4
Observer alphanumeric password setting
Security (Read Only)
32DE
Observer alphanumeric password status
Security (Read/Write)
32DF
Observer alphanumeric password entry
Security (Read Only)
32E9
Reserved for password settings of future roles (63 items)
3328
Security status indicator
Security (Read/Write Setting)
3329
Session Lockout
332A
Session Lockout Period
332B
Undefined
332C
Undefined
332E
Undefined
Security Supervisory (Read/Write Setting)
3331
Local Authentication Enable
3332
Supervisor Role Enable
3333
Lock Relay
3334
Factory Service Mode Enable
3335
Failed Authentication Alarm Enable
3336
Firmware Lock Alarm
3337
Settings Lock Alarm
3338
Bypass Access
3339
Encryption
333A
Serial Inactivity Timeout
Security Command (Read/Write Command)
3350
Operator Logoff
3351
Engineer Logoff
3352
Administrator Logoff
3353
Clear Security Data
Security Reserved Modbus Registers (Read/Write)
3360
Address 0x3360 reserved for serial login (20 items)
3374
Address 0x3374 reserved for serial logout
Security Reserved Modbus Registers (Read Only)
3375
Address 0x3374 reserved for serial logout
Event recorder actual values (read only)
3400
Events Since Last Clear
3402
Number of Available Events
3404
Event Recorder Last Cleared Date
Event recorder commands (read/write)
3406
Event Recorder Clear Command
Expanded Direct Input/Output Status (Read Only)
3560
Direct Device States, one per register (8 items)
3570
Direct Input States, one per register (96 items)
Radius Configuration (Read/Write Setting)
3735
Undefined
3737
Undefined
GE Multilin
RANGE
---
0 to 1
---
---
0 to 1
---
0 to 65535
0 to 65535
0 to 99
0 to 9999
0 to 1
0 to 4294967295
0 to 65535
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
1 to 9999
0 to 1
0 to 1
0 to 1
0 to 1
0 to 9999
0 to 9999
0 to 5
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 1
0 to 1
0 to 1
0 to 4294967295
1 to 65535
B90 Low Impedance Bus Differential System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
---
F202
---
1
F102
---
---
F202
---
---
F202
---
1
F102
---
---
F202
---
1
F001
---
1
F618
---
1
F001
min
1
F001
---
1
F126
---
1
F003
---
1
F001
---
1
F126
---
1
F102
---
1
F102
---
1
F102
---
1
F102
---
1
F102
---
1
F102
---
1
F102
---
1
F102
---
1
F001
---
1
F126
---
1
F126
---
1
F126
---
1
F126
---
1
F001
---
1
F001
---
1
F617
---
1
F003
---
1
F003
---
1
F050
---
1
F126
---
1
F155
---
1
F108
---
1
F003
---
1
F001
DEFAULT
(none)
0 (Disabled)
(none)
(none)
0 (Disabled)
B
(none)
0
0
3
3
0 (No)
0
514
1 (Yes
0 (Disabled)
0 (Disabled)
0 (Disabled)
1 (Enabled)
1 (Enabled)
1 (Enabled)
0 (Disabled)
1 (Enabled)
1
0 (No)
0 (No)
0 (No)
0 (No)
3
3
3 (Engineer)
0
0
0
0 (No)
0 (Offline)
0 (Off)
56554706
1812
B-13