Data Carrier Installation - Omron V600-CA1A Operation Manual

V600 series r/w heads and sram data carriers
Table of Contents

Advertisement

Data Carrier Installation

400 mm min.
Proximity
sensor
V600-H11 R/W Head
100 mm min.
Proximity
sensor
4-2

Data Carrier Installation

V600-D8KR12/KR13/KR04 Data Carriers
Installation Method
26
perpendicular. When the two are facing each other, they should be at least 300
mm apart.
Proximity
sensor
400 mm min.
As shown in the following diagrams, a V600-H11 R/W Head should be at least
100 mm from a proximity sensor regardless of whether the two are parallel, per-
pendicular, or facing each other.
Proximity
sensor
100 mm min.
Use M4 screws and spring washers for DC installation. Tighten the screws to a
torque of 0.7 to 1.2 NSm (approximately 7 to 12 kgfScm).
300 mm min.
Proximity
sensor
100 mm min.
Proximity
sensor
Section
4-2
V600-H07
V600-H11

Hide quick links: