Omron V600-CA1A Operation Manual page 31

V600 series r/w heads and sram data carriers
Table of Contents

Advertisement

Data Carrier Installation
When Combined With V600-H07
R/W Head
Gap between R/W Head and metal (x)
Effect of Misalignment
V600-D2KR16 Data Carriers
Installation Method
28
When the V600-D8KR04 is flush-mounted in a metal casing, the transmission
range varies according to the width of the gap (x) between the metal and the DC,
as shown in the following graphs.
±
(Shaft slip:
0 mm)
DC
(over 100 mm)
The transmission range will be reduced if the R/W Head does not face the DC
directly when data is transmitted. Try to keep any misalignment below 10°, as
shown in the following diagram.
Correct
DC
Read/Write Head
Use a special-purpose holder (purchased separately) for installation. First
secure the holder with flat countersunk-head screws in at least two places, and
tighten the screws to a torque of 0.3 to 0.5 NSm (approximately 3 to 5 kgfScm).
Then insert the DC into this holder by hand.
Be sure to attach the battery cover seal to the back of the DC. If this seal is not
affixed, the IP protective structure standards will not be satisfied.
(Four, 3.5 dia.)
(Four, 5.5 dia.)
When Combined With V600-H11
(Shaft slip:
R/W Head
Gap between R/W Head and metal (x)
Incorrect
DC
θ
Read/Write Head
Section
4-2
±
0 mm)
DC
(over 100 mm)
This angle should
not exceed 10°.