Specifications; Default Settings - HID ENTRYPROX User Manual

Table of Contents

Advertisement

EntryProx User Manual, 4045-905, Rev. C.4

2.4 Specifications

Category
Environmental
Operating
Temperature
Operating Humidity
Electrical
Power
Supply/Current
Requirements
Mechanical
Height
Width
Depth
Relay Outputs
Main Relay, Aux
Relay
Sounder
LEDs

2.5 Default Settings

The EntryProx unit is shipped with the following default settings.
Parameter
Master Code (User Location 1)
Code must be changed before programming the unit.
Main Relay energizes for
Audible Keypress Feedback
Local Propped Door Sounder activates after
Local Forced Door Sounder activates immediately for
Data Output Port
September 2016
Requirement
–31˚F to 150˚F
(-35˚C to 66˚C) @ 30 VDC
5 to 95% relative humidity,
non-condensing
10 - 15V DC, linear, filtered and regulated power supply recommended 150 mA
for the EntryProx unit only.
Additional capacity or separate supply required for locking device or
peripherals.
5.25 in (13.3 cm)
2.75 in (7 cm)
1.625 in (4.1 cm)
Form C (switches up to 1A inductive load, 2A resistive @ 30VDC)
4000 Hz, defeatable
Bi-Color (red/green)
Amber
Infrared
Default Setting
1234*
5 seconds
ON
30 seconds
10 seconds
Infrared (IR) port
Page 7 of 38