3 TECHNICAL DATA

3
TECHNICAL DATA
NOTE!
The MobileFeed 301 AVS is not recommended for short circuiting transfer using
constant current power sources due to the limited short circuit current available
on constant current power sources.
Wire feed speed
Primary input (open circuit voltage or arc voltage) Not for use with AC power
Minimum
Welding
Maximum
Standard spindle hub
Standard spool
Maximum welding current
Maximum gas inlet pressure
Wire diameters
Hard
Soft
Cored
Motor type
Brake type (wire)
Control
Feed system
On-Off switch
Ramp start
Height × Width × Length
Weight (with contactor, without spool) 33 lbs (15 kg)
Enclosure class
Enclosure class
The IP code indicates the enclosure class, i. e. the degree of protection against penetration
by solid objects or water.
Equipment marked IP 23S is intended for indoor and outdoor use; however, should not be
operated in precipitation.
0558 012 634
MobileFeed 301 AVS
50 – 750 in/min (1.3 – 19.0 m/min)
14 V DC
45 V DC (when welding)
100 V DC (113 V peak)
2" (50 mm) ID
8" (200 mm) OD, 12" (300 mm) OD
320 A at 60 % duty cycle
250 A at 100 % duty cycle
75 psi (5.2 Bar)
.030" (0.8 mm), .035" (0.9 mm),
.045" (1.2 mm), .052" (1.4 mm),
1/16" (1.6 mm)
.035" (0.9 mm), 3/64" (1.2 mm),
1/16" (1.6 mm)
.030" (0.8 mm), .035" (0.9 mm),
.045" (1.2 mm), .052" (1.4mm),
1/16" (1.6 mm), 5/64" (2.0 mm)
DC permanent magnet pre-lubricated, enclosed
Drag
Solid state
Push
Standard
Standard
17.0" × 8.3" × 21.0" (432 × 210 × 534 mm)
IP23S