MAC TOOLS MDT 10 Operator's Manual page 39

Scan tool
Table of Contents

Advertisement

Non-Continuous Tests
Mode 6 views onboard monitoring test results for noncontinuous monitor systems.
1. Select Non-Continuous Tests from the Generic OBDII screen
2. Follow the prompts on the screen.
Non-Continuous Monitor Tests (Mode 6) are a pass/fail test. Some examples are certain EVAP tests, catalyst,
and EGR. The following information is reported:
• ECU.
• TID (test identification) which indicates the system monitor.
• CID (component identification) which indicates the component tested and its test value.
• Minimum value, maximum value, and current value for each non-continuous monitor supported.
• Pass or fail test results.
Each vehicle manufacturer assigns a code number to their system monitors and components. Refer to the vehi-
cle manufacturers Mode 6 code chart to determine the failure indicated by the TID and CID. If this chart is not
available, run an automated system test (AST) from the DTC screen and select Mode 6. See Read DTCs section
for more information regarding steps to complete that action.
800.MACTOOLS
ss02425
Current
Generic OBDII
READINESS MODE 1
Oxygen Sensor Tests (Mode 5)
DATA STREAM MODE 1
FREEZE FRAME MODE 2
DTC's MODES 3,4,7,A
Component parameters may not be valid if Readiness Status is 'Not
O2 SENSORS MODE 5
Ready'.
NON-CONTINUOUS TESTS
MODE 6
SPECIAL TESTS MODE 8
VEHICLE INFO MODE 9
ss02427
Current
Generic OBDII
READINESS MODE 1
Non-Continuously Monitored Tests
(Mode 6)
DATA STREAM MODE 1
FREEZE FRAME MODE 2
ECU: ENGINE
DTC's MODES 3,4,7,A
TID 1
CID 1
O2 SENSORS MODE 5
N/A
NON-CONTINUOUS TESTS
MIN
MODE 6
TID 2
SPECIAL TESTS MODE 8
CID 2
N/A
VEHICLE INFO MODE 9
MIN
TID 3
CID 3
N/A
MIN
CANCEL
OK
TID 1
TID 1
62038
3776
VALUE
MAX
TID 2
TID 2
3073
21587
VALUE
MAX
TID 3
TID 3
55785
27062
VALUE
MAX
Failed
N/A
UNITS
Passed
N/A
UNITS
Failed
N/A
UNITS
39