Ek280 Operation And Display; Display Configuration; Main" Main Display; Setting The Number Of Tabs - Elster EK280 Applications Manual

Hide thumbs Also See for EK280:
Table of Contents

Advertisement

EK280

2 EK280 Operation and Display

2.1 Display configuration

2.1.1 "Main" main display

With the calibration lock open,
for the
"Main"
tab:
"Main"
Description
volume +
Displayed: Volume at base conditions, volume at measurement conditions,
meas.
pressure, temperature, compressibility and conversion factor with short descriptions
Meter reading format: 8 digits before and 3 digits after decimal point
volume short
Displayed: Volume at base conditions and volume at measurement conditions with
short descriptions and header
Meter reading format: 8 digits before and 3 digits after decimal point
volume long
Displayed: Volume at base conditions and volume at measurement conditions with
header but without short descriptions
Meter reading format: 9 digits before and 4 digits after decimal point
Volume, p,T,Q
Displayed: Volume at base conditions, volume at measurement conditions,
pressure, temperature, standard load and operational load with short descriptions
Meter reading format: 8 digits before and 3 digits after decimal point
List
Displayed: Volume at base conditions, volume at measurement conditions, total
number of DE1 inputs (initial number for connected Encoder), pressure,
temperature, conversion factor, compressibility, operational load, standard load,
date and time
Vb, Vo, meas.
The following are displayed: Volume at base conditions, meter reading of the gas
meter (Encoder), pressure, temperature, compressibility ratio factor and conversion
factor with short descriptions
Meter reading format: 8 digits before and 3 digits after decimal point
Vb,Vo,p,T,Q
The following are displayed: Volume at base conditions, meter reading of the gas
meter (Encoder), pressure, temperature, standard load and operational load with
short descriptions
Meter reading format: 8 digits before and 3 digits after decimal point

2.1.2 Setting the number of tabs

With the calibration lock open, on the "Ctrl." display tab the
tabs displayed.
"Menu"
Description
2 registers
The
3 registers
The Main,
4 registers
The Main, Cust.,
5 registers
All Main, Cust., Admin,
-
This option is system-generated and is not intended for use. It works in the same
way as
Application Manual
"Main"
on the
"Ctrl."
Main
and
Ctrl.
tabs will be displayed.
Cust.
and
Ctrl.
tabs will be displayed.
Admin
and
Serv.
"2
registers" (see above).
display tab allows you to select different views and contents
"Menu"
value allows you to select the number of
Ctrl. tabs
will be displayed.
and
Ctrl.
tabs will be displayed.
6