7.2.4 EM260 with GSM-Modem

Initial conditions:
The EM260 is connected as described in Chapter 7.2.1. It is connected but it must not be live.
7.2.4.1 Parameterization of the EK280 for operation with an EM260/GSM
i
For parameterization of the EK280 you will require a connection cable for the optical interface as
well as the enSuite application, which can be downloaded for free at www.elster-instromet.com.
a)
Closing the time windows
In order that the parameterization works correctly the time windows 5 and 6 must be closed. Proceed
as described in Section 7.2.2.1 on page 69 .
b)
Send parameter file
Send the following parameter file to the EK280 (see Chapter 3.6, page 17):
EK280_xvx.. - EM260 & int. M2106x – GSM (*)
For any further individual settings and tests required, press "Navigation" on the left-hand side and
then
"Parameterize
i
All the values listed in enSuite under "Parameters" can be found on the "Serv." display tab of the
EK280 under the same path.
i
The EK280 will only work with an EM260 model from year 2009 with a Baud rate of 19200. EM260
devices before 2009 need to be operated with a Baud rate of 9600.
c)
Setting time window for potential data retrievals
i
Before the first time opening of a time window, the EM260 must first be connected to the EK280 in
accordance with Section 7.2.1 and must have been parameterized pursuant to Section 7.2.4.2!
The call time window maybe set up with enSuite via the optical interface of the EK280 via the path
"Parameters" > "Interfaces" >
7.2.4.2 Parameterization of the EM260-integrated GSM modem
Parameterization of the EM260-integrated GSM modem is only possible with the EM260 housing open and
supplied with 230 VA supply voltage, and only suitably qualified personnel is permitted to do so.
CAUTION! 230 V alternating current Risk to life!
i
For the parameterization of the GSM modem in the EM260 for operation with an EK280 you will
need a commercial DSUB9-RS232 cable (1.1 through-contacted, no null modem cable, and the
program ModemIni version V3.50 or later which you can request free of charge from Elster.
For parameterization of the GSM modem in EM260, please proceed as follows:
Make sure that time windows 5 and 6 of the EK280 are closed.
Make sure that there is no power to EM260.
8
The "x" stands for the version of software on the device, e.g. "2v2".
The star * stands for a small letter which indicates the version of the file, e.g. "a".
Application Manual
online" at the bottom of the navigation window.
"Call time
windows"
8
77