Emerson Rosemount 2051 Quick Start Manual page 6

Pressure transmitter; 2051cf series flowmeter
Hide thumbs Also See for Rosemount 2051:
Table of Contents

Advertisement

Quick Start Guide
2.4 Bolting considerations
If the transmitter installation requires assembly of the process flanges, manifolds,
or flange adapters, follow the assembly guidelines to ensure a tight seal for
optimal performance characteristics of the transmitters. Use only bolts supplied
with the transmitter or sold by Emerson
illustrates common transmitter assemblies with the bolt length required for
proper transmitter assembly.
Figure 3. Common Transmitter Assemblies
A
4 × 1.75-in.
(44 mm)
B
4 × 2.88-in.
(73 mm)
A. Transmitter with coplanar flange
B. Transmitter with coplanar flange and optional flange adapters
C. Transmitter with traditional flange and optional flange adapters
D. Transmitter with coplanar flange and optional manifold and flange adapters
Bolts are typically carbon steel or stainless steel. Confirm the material by viewing
the markings on the head of the bolt and referencing
not shown in
representative for more information.
Carbon steel bolts do not require lubrication and the stainless steel bolts are
coated with a lubricant to ease installation. However, no additional lubricant
should be applied when installing either type of bolt.
Use the following bolt installation procedure:
1. Finger tighten the bolts.
2. Torque the bolts to the initial torque value using a crossing pattern.
See
Table 2
3. Torque the bolts to the final torque value using the same crossing pattern.
See
Table 2
4. Verify the flange bolts are protruding through the sensor module bolt holes
before applying pressure.
6
C
4
×
1.75-in.
(44 mm)
Table
2, contact a local Emerson Process Management
for initial torque value.
for final torque value.
as spare parts.
4 × 2.25-in.
(57 mm)
4
×
1.50-in.
(38 mm)
Table
September 2016
Figure 3 on page 6
D
4 × 1.75-in.
(44 mm)
2. If bolt material is

Advertisement