Testing - CEECO WPP-531-FD-ADA-AA-RP Service Manual

Hands free weatherproof telephone, stainless steel panel telephone with optional ada feature equipped with spk1.07 unvlr1 firmware
Table of Contents

Advertisement

7.0

TESTING

Assuming that the phone was programmed to automatically dial an emergency
number, and also allow use of the keypad for normal calls, without automatically
dialing a number when the black "CALL" button is pressed, the following should
apply:
Action:
Reaction:
Action:
Reaction:
Action:
Reaction:
Action:
Reaction:
NOTE:
With the phone connected to a working phone line,
Press the black "CALL" button.
The LED lights red and dial tone is received. Any number
programmed in the #18 Location will automatically dial out.
Otherwise the phone will allow normal calls to be made with the
keypad. Remember that if call restrictions are set, the phone will
only allow those calls to be made that have been programmed into
the #71-#89 Locations.
Dial a number. The LED will flash red and green during the
ringing cycle.
The called party answers. The LED turns green (after a maximum
of four seconds). A normal speakerphone conversation is allowed.
The keypad remains active for use within the boundaries set at
programming.
Finish the conversation.
Press the "CALL" button, or wait until time-out occurs
(if programmed as such).
The LED goes out.
The call is terminated.
Press the "EMER" button. The LED lights red.
The preprogrammed number is automatically dialed (SEE
SECTION 2, LOCATION #01) and will not disconnect unless the
black "CALL" button is pushed, the called party hangs up and a
wink back is received, or a programmed time out disconnect
occurs, at which time the LED goes out. During the ringing cycle,
the LED flashes red and green. When the call is answered, the
LED turns green (after a maximum of four seconds) and a normal
speakerphone conversation is allowed.
If you experienced any trouble during the testing phase, please
refer back to the appropriate section(s) of the manual. Remember
that the mini-jumpers must be moved to "ON" for programming
and to "OFF" for operation. If trouble persists, refer to section
11.2 please.