Operation; Recommended Tools And Test Equipment - CEECO WPP-531-FD-ADA-AA-RP Service Manual

Hands free weatherproof telephone, stainless steel panel telephone with optional ada feature equipped with spk1.07 unvlr1 firmware
Table of Contents

Advertisement

4.0

OPERATION

4.1
To make a call, press the black "CALL" button located on the front of the
phone. The LED will light red at this time. When dial tone is received,
the transmitter is muted and the phone waits for numbers to be dialed.
Any programmed PBX number (#18 Location) will automatically dial out.
The LED will flash red and green during the ringing cycle. When the call
is answered, the LED will turn green (after a maximum of four seconds),
and a normal speakerphone conversation may take place.
4.2
To make an Emergency call, press the red "EMER" button located on the
front of the phone. The LED will light red at this time. The
preprogrammed number will dial out on the line. Any programmed PBX
number (#02 Location) will automatically dial out first. The LED will
flash red and green during the ringing cycle. When the call is answered,
the LED will turn green (after a maximum of four seconds), and a normal
speakerphone conversation may take place.
4.3
After the call is complete, press the "CALL" button again to terminate the
call. The LED will go out. If user does not press the "CALL" button
when he or she is finished using the phone, the phone will hang-up after
detecting a WINK (momentary open) or when the timer times-out, if it
was so programmed.
4.4
If digit 1 of Location #00 is "0", then call restrictions are in effect. The
numbers that may be dialed are restricted to the numbers entered into
Location #71-#89. If the number dialed is not in the Location #71-#89,
then the phone gives three tones and drops the line.
4.5
If remote programming is being utilized and has been programmed, call
into the CEECO telephone from another telephone. Follow the
instructions from the programming section to perform the remote
programming.
5.0

RECOMMENDED TOOLS AND TEST EQUIPMENT

DTMF Test Set
Volt/Ohm Meter
3/8" Nut Driver
5/16" Nut Driver
Flat Blade Screw Driver
Security Tool, CEECO Part Number 301-064
If digit 1 of Location #00 is "1" then there are no
restrictions and any number may be dialed.