SG 05.1
SG 12.1/SGR 05.1
AC 01.2 Non-Intrusive Profibus DP
4.4
Mounting positions of local controls
4.4.1
Mounting positions: modify
SGR 12.1 Control unit: electronic (MWG)
8.
Fasten actuator with screws [4].
Information: We recommend glueing the screws using sealing material to avoid
contact corrosion.
Fasten screws [4] crosswise with a torque according to table:
Table 2:
Tightening torques for screws
Screws
Thread
M6
M8
M10
M12
The mounting position of the local controls is selected according to the order. If, after
mounting the actuator to the valve or the gearbox on site, the local controls are in
an unfavourable position, the mounting position can be changed at a later date. Four
mounting positions are possible.
Figure 7:
Mounting positions A-2 and B-2
Figure 8:
Mounting positions C-2 and D-2
Hazardous voltage!
Risk of electric shock.
Disconnect device from the mains before opening.
Tightening torque T
[Nm]
A
Strength class 8.8
11
25
51
87
Assembly
13