Power & Ground Wiring; Operations Instructions - FDS FD090CV Installation And Operation Manual

9” tft lcd
Table of Contents

Advertisement

Power and Ground Wiring
This is a 28VDC monitor that requires 1 amp of power to operate. To operate
properly this monitor requires an input voltage of 18-29VDC.
The rated current of the equipment and associated voltage drop should be taken
into consideration when selecting wire gauge. The following example is based on
an install with a 28VDC power system and a total of 50 feet of wire between the
circuit breaker, monitor and ground.
Example: 22awg wire has 16.2 Ohms per 1000 feet, this equates to .81 Ohms for 50
feet. 1 Amp of current on .81 Ohms will drop .81 Volts.
Also, use short heavy gauge wire and a clean tight connection for ground.
It is the installer's responsibility to understand the product's requirements to install
the product in compliance with industry standards and safety.
Operation Instructions
The FD090CV is continuously on but can be de-energized by removing power from the
entertainment system. No pilot or aircrew action is necessary during flight or ground
operation. Passengers can change the video output from the FD090CV using the remote
control.
NOTE: The HDMI Input on the FD090CV is not HDCP complaint therefore will not
work with certain source devices such as Blu-Ray players.
© 2015 FDS Avionics Corp.
All Rights Reserved.
Document Number:
MAN – FD090CV
Resistance of Wire Type M22759/16-**
(** = Gauge)
Gauge (AWG)
24
22
20
16
12
10
8
Revision Date:
Rev:
B
Page 10 of 19
OHMS/1000'
26.20
16.20
9.88
4.81
2.02
1.26
.701
TECHNICAL SUPPORT
470-239-7421 or FDSAvionics.com
01/10/2017

Advertisement

Table of Contents
loading

Table of Contents