Power And Ground Wiring; Rear View With Connectors; Power/Video - FDS FD215CV-C-6 Installation And Operation Manual

21.5” lcd display
Table of Contents

Advertisement

Power and Ground Wiring

20 AWG wire is recommended for Power and Ground applications.

Rear View with Connectors

Power/Video

Pin out for VGA - High Density DB-15 Receptacle (supplied)
Connector
Crimp Contacts
© 2017 FDS Avionics Corp.
All Rights Reserved.
Document Number:
MAN – FD215CV-C-6
PIN
NUMBER
1
Red Video
2
Green Video
3
Blue Video
4
N/C
5
N/C
6
Red Return (Ground)
7
Green Return (Ground)
8
Blue Return (Ground)
9
N/C
10
Sync Return (Ground)
11
N/C
12
DDC Data
13
Horizontal Sync
14
Vertical Sync
15
DDC Clock
P/N: M24308/2-286 or Equivalent
P/N: M39029/57-354 or Equivalent
DESCRIPTION
Revision Date:
Rev:
B
Page 7 of 16
TECHNICAL SUPPORT
470-239-7421 or FDSAvionics.com
01/11/2017