JRC JMA-5912-6 Instruction Manual page 330

Marine radar equipment
Table of Contents

Advertisement

3. Set the baud rate of the port to be set.
Selection value
The bold values are factory-set.
The COMPASS port is a receive-only port that is dedicated to COMPASS signals.
[II] Reception Port Setting (RX Port)
Set the numbers of ports for receiving signals from sensors.
There are two methods for receiving signals: specifying a port for each sensor, or using the automatic
recognition function without specifying ports.
Procedures
1. Open the Serviceman Menu.
2. Open the RX Port menu by performing the following menu operation.
3. Set a port for each sensor.
1. COMPASS
: 4800(NMEA)/9600(NSK)/38400(Fast NMEA) bps
2. NAV1
: 1200/4800/9600/38400 bps
3. NAV2
: 1200/4800/9600/38400 bps
4. GPS
: 1200/4800/9600/38400 bps
5. NMEA
: 1200/4800/9600/38400/115200 bps
2. Installation Menu
→ 5. COM Port Setting
Settable sensor signals
GPS, DLOG, Alarm, Depth, Temperature, Wind, Current, ROT, RSA
Selectable ports
When the automatic recognition function is used: AUTO
When ports are specified: NAV1, NAV2, GPS, and NMEA
→ 2. RX Port
7-11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Jma-5922-7/9Jma-5932-12