11.4 System > Logging
Logging Settings
General:
"Set debug output to syslog"
if this checkbox is activated, the logging is extended by the "Debug in-
formation".
"Log also to USB-Device"
additional logging outputs can only be accessed on the USB stick,
which is connected to the mbNET.mini (file name of the logging file:
"Device name.log").
Remote Logging:
"Enable Remote logging"
if this checkbox is activated, the mbNET.mini system logging can be
outsourced to another computer.
"Remote IP Address"
enter here the IP address of the external logging server.
"Remote Port"
port 514 is preset here.
We recommend that you do not change this port, unless you are using
a certain application that reacts to a different port.