48
9.3

FLAME CHARACTERISTICS

It is important to periodically perform a visual check of the pilot
EN
and burner fl ames. Compare them to the illustration provided. If
any fl ames appear abnormal, call a service person.
LOG BURNER
GLASS BURNER
CRADLE
W415-1285 / F / 12.21.16
PILOT
BURNER
FLAME
SENSOR
ELECTRODE
VEILLEUSE
LA SONDE
DE FLAMME
ÉLECTRODE
FLAME SENSOR
PILOT
ELECTRODE
3/8" - 1/2"
BURNER
(9.5mm - 12.7mm)
3/8" - 1/2"
(9.5mm - 12.7mm)
ELECTRODE
FLAME
SENSOR
FLAME MUST ENVELOP
UPPER 3/8" (9.5mm) TO 1/2"
FLAME MUST ENVELOP
(12.7mm) OF FLAME SENSOR
UPPER 3/8" (9.5mm) TO 1/2"
(12.7mm) OF FLAME SENSOR
ÉLECTRODE
54.1B
3/8" - 1/2"
(9,5mm - 12,7mm)
LA SONDE
DE FLAMME
LA SONDE DE FLAMME
3/8" - 1/2"
(9.5mm - 12.7mm)
ÉLECTRODE
LA FLAMME DOIT ENVELOPPER
LA PARTIE SUPÉRIEURE DE LA
SONDE DE FLAMME DE 3/8"
(9.5mm) À 1/2" (12.7mm)
PILOT
BURNER
VEILLEUSE
VEILLEUSE
LA FLAMME DOIT
ENVELOPPER LA PARTIE
SUPÉRIEURE DE LA SONDE
DE FLAMME DE 3/8" (9,5mm)
À 1/2" (12,7mm)