5.1 Door Count Installation Requirements

For accurate count, Ax47DC installation must comply with all requirements below:
1. Mounting height between 2.43m (8') and 3.65m (12') Above Finished Floor (AFF).
Reliability decreases outside of this range.
2. Centered on doorway and 1.22m (4') in from the doorway.
3. Field of View must be adjusted so that the camera views through the doorway
with the top of the image aligned between the top of the doorway and half-way
down to the bottom of the doorway. Do not cut off more than the top half of the
doorway. The width of the image
should be about 2 to 2½ times
the width of the doorway. Sharp
focus is essential. Hanging signs,
banners, balloons, etc., in the
field of view will interfere with the
counting results.
Ax47DC Camera (Top View)
Doorway (Top View)

5.2 Disassembling the Camera

Before mounting and adjusting the camera, follow these steps to disassemble the
camera.
1. Use the provided security Torx key to loosen three screws securing the dome
bubble housing to camera module. Do not completely remove the screws from the
dome bubble.
2. Gently pull the dome bubble downwards and set aside.
i3-TRNG-CAMS-Ax47DC-UM.indd
Centered
on and
1.2m
(4 ft)
from the
doorway
Ax47DC Camera (Side View)
Doorway (Side
11
Centered
on and
1.2m
(4 ft)
from the
doorway
Finished
Floor
View)
Rev. 170322