6. Center Voltage Adjustment (PD-166 board)

Set the center level of video signal for driving the LCD to the
specified value.
Mode
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Note: Check that the data of page: 0, address: 10 is "00".
Adjusting method:
Order Page Address Data
1
0
01
2
C
6A
3
C
6A
4
0
01
CAMERA
Not required
Pin 1 of CN803 (VG)
Digital voltmeter
C
6A
A = 7.00 ± 0.05 Vdc
Procedure
01
Change the data and set the
DC voltage (A) to the
specified value. (The data
should be "00" to "7F")
Press PAUSE button.
00

7. V-COM Adjustment (PD-166 board)

Set the DC bias of the common electrode drive signal of LCD to
the specified value.
If deviated, the LCD display will be move, producing flicker and
conspicuous vertical lines.
Mode
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Note 1: Perform "RGB AMP Adjustment", "Black Limit Adjust-
ment", "PSIG GRAY Adjustment", "Contrast Adjust-
ment" and "Center Voltage Adjustment" before this ad-
justment.
Note 2: Check that the data of page: 0, address: 10 is "00".
Adjusting method:
Order Page Address Data
1
0
01
2
C
63
3
C
63
4
C
63
5
0
01
5-40
CAMERA
Not required
Check on LCD screen
C
63
The brightness difference between
the section-A and section-B is
minimum
Procedure
01
Change the data so that
brightness of the section A
and section B is equal.
Subtract 2 from the data.
Press PAUSE button.
00
B
A
A
B
B
A
A
B
Fig. 5-1-22

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dcr-pc101

Table of Contents