RadarW
RadarW
RadarW
RadarW
RadarW
17. CCD Defect Check
Subject
Not required
Measurement Point
Check on the monitor TV
Measuring Instrument
Note: Check that the data of page: 0, address: 10 is "00".
Switch setting
1) POWER ................................................................... CAMERA
2) NIGHT SHOT .................................................................. OFF
Checking method:
Order Page Address Data
1
6
01
05
2
6
1F
CC
3
4
6
40
03
5
6
6
40
04
7
8
6
40
05
9
10
6
40
06
11
Processing after Completing Adjustment:
Order Page Address Data
1
6
01
00
2
6
40
00
3
6
1F
00
Procedure
Press PAUSE button.
Check on the monitor screen
that no defect is found.
Check on the monitor screen
that no defect is found.
Check on the monitor screen
that no defect is found.
Check on the monitor screen
that no defect is found.
Check on the monitor screen
that no defect is found.
Procedure
Press PAUSE button.
5-33
DCR-PC101/PC101E