Hall Adjustment; Mr Adjustment - Sony DCR-PC100 Service Manual

Digital video camera recorder
Hide thumbs Also See for DCR-PC100:
Table of Contents

Advertisement

3. HALL Adjustment

For detecting the position of the lens iris and ND filter, adjust each
AMP gain and offset.
Subject
Not required
Measurement Point
Display data of page 1 (Note1)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
17, 18, 19, 1A, 1B, 1C
Specified Value
When the data of page: 6, address: 01
is "01": 15 to 19 (Note2)
When the data of page: 6, address: 01
is "03": 87 to 8B (Note2)
When the data of page: 6, address: 01
is "69": 87 to 8B (Note2)
When the data of page: 6, address: 01
is "6B": 15 to 19 (Note2)
Note1: Displayed data of page 1 of the adjustment remote commander.
1 : 00 : XX
Note2: The PAUSE button of the Adjustment remote commander must be
pressed.
Switch setting:
POWER .................................................................. CAMERA
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 6, address: 94, and set data: 17.
3) Select page: 6, address: 95, and set data: 89.
4) Select page: 6, address: 01, set data: 6D, and press the PAUSE
button of the adjustment remote commander. (The HALL
adjustment is performed and the adjustment data is stored in
page: F, address: 17 to 1C.)
5) Select page: 6, address: 02, and check that the data is "01".
6) Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
Checking method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: F, address: 10, set data: 39, and press the PAUSE
button.
3) Select page: 6, address: 01, set data: 01, and press the PAUSE
button.
4) Select page: 1, and check that the display data (Note1) satisfies
the specified value.
5) Select page: 6, address: 01, set data: 03, and press the PAUSE
button.
6) Select page: 1, and check that the display data (Note1) satisfies
the specified value.
7) Select page: F, address: 10, set data: 43, and press the PAUSE
button.
8) Select page: 6, address: 01, set data: 69, and press the PAUSE
button.
9) Select page: 1, and check that the display data (Note1) satisfies
the specified value.
10) Select page: 6, address: 01, set data: 6B, and press the PAUSE
button.
11) Select page: 1, and check that the display data (Note1) satisfies
the specified value.
Processing after Completing Adjustments:
1) Select page: F, address: 10, set data: 00, and press the PAUSE
button.
2) Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
3) Select page: 6, address: 94, and set data: 00.
4) Select page: 6, address: 95, and set data: 00.
5) Select page: 0, address: 01, and set data: 00.
Display data

4. MR Adjustment

The MR (Magnet resistor) adjustment of the inner focus lens is
carried out automatically. In whichever case, the focus will be
deviated during auto focusing/manual focusing.
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Note: Make the lens horizontal and perform this adjustment.
Switch setting:
POWER .................................................................. CAMERA
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 6, address: 01, set data: BD, and press the PAUSE
button of the adjustment remote commander. (The MR
adjustment is performed and the adjustment data is stored in
page: F, address: 50 to 59, 62.)
3) Select page: 6, address: 02, and check that the data is "01".
4) Select page: F, address: 50, and check that the data satisfies the
specified value.
5) Select page: F, address: 51, and check that the data satisfies the
specified value.
Processing after Completing Adjustments:
1) Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
2) Select page: 0, address: 01, set data: 00.
3) Turn off the power and turn on again.
4) Perform "Flange Back Adjustment".
5-22
Not required
Adjustment remote commander
F
50 to 59, 62
The data of page: F, address: 50 is
"40" to "C0"
The data of page: F, address: 51 is
"40" to "C0"

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dcr-pc100e

Table of Contents