Servo And Rf System Adjustment; Cap Fg Duty Adjustment (Mr-40 Board); T-Reel Fg Duty Adjustment (Mr-40 Board); Pll F & Lpf F Adjustment (Mr-40 Board) - Sony Handycam DCR-PC1 Service Manual

Digital video camera recorder
Hide thumbs Also See for Handycam DCR-PC1:
Table of Contents

Advertisement

3-4.

SERVO AND RF SYSTEM ADJUSTMENT

Before performing the servo and RF system adjustments, check that
the specified value of "36 MHz Master Oscillator Adjustment" of
"CAMERA SYSTEM ADJUSTMENT" is satisfied.
Adjusting Procedure:
1.
Cap FG duty adjustment
2.
T-reel FG duty adjustment
3.
PLL f
& LPF f
adjustment
0
0
4.
Switching position adjustment
5.
AGC center level adjustment
6.
APC & AEQ adjustment
7.
PLL f
& LPF f
final adjustment
0
0

1. Cap FG Duty Adjustment (MR-40 board)

Set the Cap FG signal duty cycle to 50% to establish an appropriate
capstan servo. If deviated, the uneven rotation of capstan and noise
can occur.
Measurement Point
Display data of page: 3, address: 03
Measuring Instrument
Adjustment remote commander
Adjustment Page
C
Adjustment Address
16
Specified Value
00
Adjusting Method:
1)
Close the cassette compartment without inserting a cassette.
2)
Select page: 0, address: 01, and set data: 01.
3)
Select page: 3, address: 01, set data: 1B, and press the PAUSE
button of the adjustment remote commander.
4)
Select page: 3, address: 02, and check that the data changes
starting from "1B" to "2B" to "00" in this order.
5)
Select page: 3, address: 03, and check that the data is "00".
Note: If the data of page: 3, address: 03 is "02", adjustment has errors
or the mechanism deck is defective.
6)
Select page: 0, address: 01, and set data: 00.

2. T-reel FG Duty Adjustment (MR-40 board)

Adjust the take-up reel FG signal duty cycle to an appropriate value
so that the correct T-reel FG signal is obtained.
Measurement Point
Display data of page: 3, address: 03
Measuring Instrument
Adjustment remote commander
Adjustment Page
C
Adjustment Address
17
Specified Value
00
Adjusting Method:
1)
Close the cassette compartment without inserting a cassette.
2)
Select page: 0, address: 01, and set data: 01.
3)
Select page: 3, address: 01, set data: 1C, and press the PAUSE
button of the adjustment remote commander.
4)
Select page: 3, address: 02, and check that the data changes
starting from "1C" to "2C" to "00" in this order.
5)
Select page: 3, address: 03, and check that the data is "00".
Note: If the data of page: 3, address: 03 is "02", adjustment has errors
or the mechanism deck is defective.
6)
Select page: 0, address: 01, and set data: 00.
3. PLL f
& LPF f
Adjustment (MR-40 board)
0
0
Mode
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Adjusting Method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 3, address: 01, set data: 30, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 3, address: 02, and check that the data is changed
to "00".
4)
Select page: 3, address: 03, and check that the data is "00".
Note: If the data of page: 3, address: 03 is other than "00", there are
errors. (For the error contents, see the following table. For the
bit values, refer to "5-4. SERVICE MODE", "4-3. 3. Bit value
discrimination".
5)
Select page: 0, address: 01, and set data: 00.
Bit value of page: 3,
address: 03
bit 4 = 1
bit 5 = 1
bit 6 = 1
bit 3 = 1
5-35
VTR stop
Display data of page: 3, address: 03
Adjustment remote commander
C
1F, 20, 22, 47
00
Error contents
PLL f
, even channel is defective
0
PLL f
, odd channel is defective
0
LPF f
is defective
0
PLL f
final adjustment is defective
0