Description
NIC status LED*
UID button/LED*
*When all four LEDs described in this table flash simultaneously, a power fault has occurred.
**If the health LED indicates a degraded or critical state, review the system IML or use iLO to review the
system health status.
†Facility power is not present, power cord is not attached, no power supplies are installed, power supply
failure has occurred, or the power button cable is disconnected.
3
Figure 8: Front panel LEDs, HPE StoreOnce 3100 System
1
UID LED
3
System health LED
26
Identifying problems
Status
Solid green = Link to network
Flashing green (1 Hz/cycle per sec) = Network active
Off = No network activity
Solid blue = Activated
Flashing blue:
1 Hz/cycle per sec = Remote management or
firmware upgrade in progress
4 Hz/cycle per sec = iLO manual reboot sequence
initiated
8 Hz/cycle per sec = iLO manual reboot sequence
in progress
Off = Deactivated
1
2
3
4
4
2
4
NIC status LED
Power LED and on/off button