The glass gobo's are the only gobo's that are interchangable in this
unit. Remember when changing these gobo's they are glass. Please
do this process gently so you do not break the gobo. Note: There is
one metal gobo in this wheel which is also interchangable.
Caution! Never open the unit when in use. Always disconnect the
main power before attempting to change the gobos.
Locating the Gobo wheel: After disconnecting the main power, posi-
tion the head with the lens facing forward. Look through lens of the
unit. When looking through the front lens, position the head so that
the gears are on the right side. When the gears are on the right side,
the shell that needs to be uscrewed is now facing up.
1. To change a gobo, uscrew the 4 screws that secure the shell to the
unit. The shell is attached to the unit by a safety wire, gently lift the
shell off of the unit.
2. When you remove the shell you will be able to access the gobo
wheel. Turn the wheel with your hand until you come across the
gobo you would like to change.
3. You have to remove the individual gobo frames. Gently push the
gobo frame (Not the wheel) away from the gobo wheel, you do not
have to the push the gobo frame to far. While you are pushing the
gobo frame away from the wheel, pull the the gobo frame up and
out.
4. Once the gobo frame has been removed, you will notice that high
temperature silicon is applied to the retainer ring. Using a small flat
head screw driver, very gently scrape away the silicon to release
the retainer ring. After the retainer ring is removed, remove the
gobo.
5. Change the gobo and replace the retainer ring. Reapply high tem-
perature silicon or high temperature gasket sealer to the same
areas on the retainer ring.
6. Insert the gobo frame back into the unit, positioning it in same way
as the other gobo frames.
7. Reassemble the unit.
ADJ Products, LLC - www.adj.com - Vizi BSW 300 Instruction Manual Page 38
Changing the Gobo (1st Wheel)
Vizi BSW 300
With this feature you can connect the fixtures to one another
using the PowerCON input and output sockets. The quantity that
can be connected is 4 fixtures maximum @ 110V and a maximum
8 fixture's @ 240V. After maximum limit has been reached you will
need to use a new power outlet. They must be the same fixtures.
DO NOT mix fixtures.
Vizi BSW 300
Disconnect the unit from its power source. The fuse holder is located
next to the powerCON connection. Using a Phillips head screw driver
unscrew the fuse holder. Remove the bad fuse and replace with a new
10A fuse.
Vizi BSW 300
Fixture Cleaning:
Due to fog residue, smoke, and dust cleaning
the internal and external optical lenses and mirror should be carried
out periodically to optimize light output. Cleaning frequency depends
on the environment in which the fixture operates (I.e. smoke, fog
residue, dust, dew). In heavy club use we recommend cleaning on a
monthly basis. Periodic cleaning will ensure longevity, and crisp out-
put.
1. Use normal glass cleaner and a soft cloth to wipe down the out-
side casing.
2. Use a brush to wipe down the cooling vents and fan grill.
3. Clean the external optics with glass cleaner and a soft cloth every
20 days.
4. Clean the internal optics with glass cleaner and a soft cloth every
30-60 days.
5. Always be sure to dry all parts completely before plugging the unit
back in.