IP Outputs Tab

IP Outputs receive data from connected inputs, format this data for transmission over UDP/IP,
and send it with very precise timing over the Ethernet ports. The 9223 card supports up to 4
transport stream outputs per Ethernet port. IP Outputs have the following specifications:
• Formats supported:
o MPEG-2 Transport Packets over UDP/IP
o MPEG-2 Transport Packets over RTP/UDP/IP
• Number of MPEG-2 Transport Packets per UDP datagram: fixed at 7.
• Addressing support: unicast, multicast and broadcast.
• Advanced control over the IP header fields available.
• SMPTE 2022 FEC available

IP Outputs: Configuration Tab

IP output stream can be created, configured, and removed using this configuration area. Before
any streams are created, the Configuration Tab appears as depicted below:
To create an IP Output stream, first select the desired Ethernet port in the Add Stream drop-
down box. Once that selection is made, the IP Output Stream Configuration is displayed, as
depicted below (Basic View). The configuration screen has two areas:
• IP Output Parameters: these are the parameters specific to the IP Output configuration.
The set of parameters available for configuration depends on the View selection. In the
Basic view, suitable default values are entered for the advanced parameters.
• Input Selection Connection Parameters: these allow a connection to be made to the
output stream.
The Connection Parameters are common to all outputs, and will be described in the
5
Previously known as Pro-MPEG FEC COP3.
5
. The 9223 supports one FEC session per Ethernet port.