Product Tab - Cobalt Digital Inc 9223 Product Manual

Dual-channel 3g/hd/sd mpeg-4 encoder
Table of Contents

Advertisement

Product Tab

The Product Tab contains basic information about the 9223.
The following information is available:
• Build Date: Date the firmware image was built.
• Supplier: Cobalt Digital Inc.
• Product: 9223.
• Software revision: This indicates the firmware revision currently running. The format is
Major Version • Minor Version • Build Number.
• Serial Number: This is the serial number of this particular 9223 card.
• Rear Module: This indicates the status of the Rear I/O Module. It can have one of the
following states:
OK: The Rear Module is the correct module for the 9223.
o
Not Installed: The 9223 is not connected to a rear module. The card is
o
operating normally, but it will not be useful as there are no input and output
connections to it.
Wrong Module: The 9223 is connected to a rear module that was not
o
designed for it (most likely from another openGear™ vendor). Depending on the
signals present on that module, there may be a chance of damage to the 9223; It is
recommended that this situation be rectified immediately. This alarm will cause
the front status LED to turn red.
• Analog Audio Input: This indicates the type of analog audio input (balanced or
unbalanced). This field will have an indication of unknown for
unrecognized/unsupported rear I/O panels.
• Card Uptime: Indicates how long the card has been running since it was last rebooted.
• Ambient Temperature: Temperature, in degrees Cesius, of the air intake of the card
(measured at the front edge of the card).
• Internal Temperature: Temperature, in degrees Cesius, at the back of the card.
• MDP Core Temperature: Temperature, in degrees Cesius, of the core MediaStorm
processing element.
The openGear™ frame is designed to operate in environments with up to 40
o
typically a 5
C temperature raise from the external ambient to the "Ambient Temperature"
measured by the 9223. If that measurement is at 45
down the ambient temperature.
o
C or higher, action must be taken to cool
16
o
C ambient. There is
9223-OM (V2.5.0)